136 Part Number STH038 5/12
Manual Setup - Applicable when the control board is
non-operational or data from the faulty board is
suspect.
Install replacement control board and reapply power.
Dependant on firmware version the screen will either
display “Manual Setup” directly or you will need to
navigate to the screen.
If you need to navigate to the control board screen:
1. Press the Menu button.
2. Press the Down arrow until Service is highlighted,
then press the Checkmark.
3. Scroll down to Replacement Control Board and
press the Checkmark.
4. Select “Manual Setup” and press the Checkmark.
Verify the date correctly auto populates.
Yes - Go to step 5
No - Highlight date with the right arrow, then use
up/down arrows to enter the correct date. Use the
right arrow to exit the date columns.
5. Scroll down to Input Model, then use up/down
arrows to enter the model number. Use the right
arrow to exit the model columns.
6. Scroll down to Input Serial #, then use up/down
arrows to enter the model number. Use the right
arrow to exit the model columns.
7. Scroll down and select exit, then press
checkmark.