58 Part Number 000007661 6/12
Bin Thermostat
Closed?
NO
Replace Thermostat
YES
Evaporator Safety
Thermostat Closed?
NO
Chute Switch
Closed?
NO
YES
Ice Contacting
Thermostat?
Remove Ice - Allow
To Warm And Retest
Adjusting Closes
Thermostat?
Verify New Setting Cycles
Machine On/Off
Yes
No No
Yes
Evaporator Cold?
Replace Thermostat
Allow Evaporator To
Warm And Retest
Adjusting Closes
Thermostat?
Verify New Setting Cycles
Machine On/Off
Yes
No
No
Yes
Adjust Or Replace
Actuator
Ice Contacting
Actuator?
Remove Ice And
Retest
Actuator Functions?
Replace Switch
Yes
No No
Yes
Yes
Yes