Manitowoc SR1801W Dokumentacja Strona 64

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 63
64 Part Number 80-1479-3 7/10
Safety Timers
The control board has the following non-adjustable
safety timers:
The ice machine is locked into the freeze cycle for
6 minutes before a harvest cycle can be initiated.
Freeze lock is bypassed after moving the toggle
switch from OFF to ICE position for the first cycle
only.
The maximum freeze time is 60 minutes at which
time the control board automatically initiates a
harvest sequence (steps 5 & 6).
The maximum harvest time is 3.5 minutes for
single evaporators and 7 minutes for Quad
evaporator model. The control board automatically
initiates a freeze sequence (steps 3 & 4) when
these times are exceeded.