Manitowoc QF0800 Dokumentacja Strona 109

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 108
Part Number 80-1230-9 6/08 109
Water Dump Valve
The water dump valve normally does not require
removal for cleaning. To determine if removal is
necessary:
1. Locate the water dump valve and follow the vinyl
tubing to the drain.
2. Set the toggle switch to ICE and start a Freeze
cycle.
3. Observe the drain outlet for leakage.
A. If the dump valve is leaking, remove,
disassemble and clean it.
B. If the dump valve is not leaking, do not
remove it. Instead, refer to cleaning and
sanitizing procedure.
Follow the procedure below to remove the dump
valve.
4. Leaving the wires attached, press down and twist
the coil 1/8 turn, then lift the coil assembly off the
valve body.
5. Remove the nylon washer, plunger, and
diaphragm.
!
Warning
Disconnect the electric power to the ice machine at
the electric service switch box and turn off the water
supply before proceeding.
Przeglądanie stron 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 307 308

Komentarze do niniejszej Instrukcji

Brak uwag