Part Number STH044 10/13 81
Will Not Stop Dispensing
Disconnect sensor plug from sensor control board.
If the dispensing stops, replace the sensor
If the dispensing continues disconnect wires
#59 & #60 from the control board
Check resistance across control board contacts
Closed = Replace the touchless sensing control
board
Open = Dispense control board is not
functioning correctly, check control board relays
Replace the selector switch if ohm readings do not
match all three switch settings.