Part Number STH025 02/12 187
Four thermistors are located on the ice machine. They
are labeled T1, T2, T3, T4
T1 - Air or Water cooled Models
Liquid line temperature sensor located at the outlet
of the condenser.
T1 - Remote Condenser or Remote Condensing
Unit Models
Liquid line temperature sensor located at the inlet
of the receiver.
T2 - Air or Water cooled Models
Discharge line temperature sensor located near
the compressor.
T2 - Remote Condenser or Remote Condensing
Unit Models
Liquid line temperature sensor located at the outlet
of the receiver.
T3 -Single Expansion Valve Models
Suction line temperature sensor located at the inlet
of the evaporator.
T4 -Single Expansion Valve Models
Suction line temperature sensor located at the
outlet of the evaporator.